Magnetic Shield Facilities


When you install various fine tuning analyzer, which controls electric beam without any protection to the interference of magnetic field, it may cause a change of color, malfunction, or distortion.

Cases

Install environment

Description

ETC

Color changes and malfunction

TV monitor near railroad side

no color changes or changes when a train passes and color changes when a train does not pass

300mG

TV monitor, computer inside of train station

color changes or unstable data transmission during departure or arrival of train

E-beam and SEM facilities in E-beam room

Influence of rapid magnetism such as .

2mG

 Distortion

TV monitor near power cable

consistent distortion

5mG

TV monitor near electric products

consistent distortion

0.5T below permanent MRI

visual distortion by intermittent direct magnetic field in vehicles and elevator

Body effect

over 1.5T superconductivity MRI

Pace-maker holder is under influence of exposed magnetic field

5G

 

The solution of magnetic shield

Changing the route of magnetic field with the magnetic material of high permeability and low coercive force prevents the intrusion and release of unnecessary magnetism.
 

¢º Effect of shield


¢º properties of magnetic shield

Magnetic field
C
lassify

Material Properties

first magnetic
permeability
(B40)

reserved
magnetic
energy
(Hc)

¥ì§Ù/§¯

Effect of shield

Hout/Hin

dB

Low Magnetic Shield

20,000

0.057

2 ×10-2

87.5 ×103

98.8

High Magnetic Shield

15,000

0.17

50 ×10-6

5 ×103

97.5

Vastness Shield

20,000

0.0057

3 ×10-6

92.1 ×103

99.2